AIAA-2017-3927

Published: Sun 21 August 2022
Updated: Sat 18 May 2024

tags: icing tunnels

"With a thermal IPS, energy reduction can be achieved by operating in a ‘running wet’ mode under more extreme icing conditions."

Figure 6 of AIAA-2017-3926. Ice tracing from descent case reference and Re and We-π3 scaled conditions

"Evaluation of Alternative Altitude Scaling Methods for Thermal Ice Protection System in NASA Icing Research Tunnel" 1

Summary

A procedure for scaling conditions for ice protection tests is detailed.

Key Points

  1. Scaling methods for ice protection testing at sea level conditions were evaluated.
  2. The "WePi3" scaling method was recommended.
  3. The method requires in-test adjustments of heating to match reference surface temperatures.
  4. Test conditions for unheated areas will be different from those for heated areas.

Abstract

A test was conducted at NASA Icing Research Tunnel to evaluate altitude scaling methods for thermal ice protection system. Two new scaling methods based on Weber number were compared against a method based on Reynolds number. The results generally agreed with the previous set of tests conducted in NRCC Altitude Icing Wind Tunnel where the three methods of scaling were also tested and compared along with reference (altitude) icing conditions. In those tests, the Weber number-based scaling methods yielded results much closer to those observed at the reference icing conditions than the Reynolds number-based icing conditions. The test in the NASA IRT used a much larger, asymmetric airfoil with an ice protection system that more closely resembled designs used in commercial aircraft. Following the trends observed during the AIWT tests, the Weber number based scaling methods resulted in smaller runback ice than the Reynolds number based scaling, and the ice formed farther upstream. The results show that the new Weber number based scaling methods, particularly the Weber number with water loading scaling, continue to show promise for ice protection system development and evaluation in atmospheric icing tunnels.

Discussion

This is one of a series of studies on the test scaling of thermal systems. AIAA-2017-3927 outlines several prior tests that, for brevity, will not be detailed herein.

Comparison to unheated similarity

The heated scaling method has similarities to unheated ice test scaling (see NASA-CR-2004-212875 2). The impingement parameter Ko is matched in both the heated and unheated methods. Stagnation line water catch rates and heat transfer are calculated using the same airfoil radius of curvature cylinder approximations. A Weber number is matched to determine test airspeed, but different Weber numbers (We_d in unheated, We_da (We_c) in heated).

While the brief section on thermal ice-protection systems testing in NASA-CR-2004-212875 recommended matching the product β_o Ac (water catch rate, m_w below), the WePi3 method (detailed below) does not; in general, the water catch rate is scaled down in scaled test. It is not stated if heating would be scaled, so I assume that it would not be.

Heated similarity

There are significant differences from unheated scaling. Stagnation line freezing fraction n_o is not matched in the heated similarity. Recovery temperature is matched in the heated similarity, while Phi is matched to determine the air temperature static temperature in the unheated similarity. For the WePi3 method, liquid water content is selected to match a calculated ratio of stagnation line water catch rate to evaporation rate, referred to as Pi3.

So, one will not have the same test conditions for unheated and heated runs of the same flight or reference condition.

Heating is adjusted to match reference surface temperatures. This step is empirical, as detailed below. So, the test condition is not completely determined in advance (unlike unheated similarity), but requires adjustments in test.

B. Test Conditions
Three flight icing scenarios served as the reference conditions for the study. These were:
1) Descent
2) Cold hold
3) Warm Hold

The conditions for these scenarios are given in Table 1. These conditions were identical to those used in the AIWT tests, except for the angle of attack. The asymmetric airfoil and IPS used in this test called for varying the angle of attack to match the corresponding icing scenarios. The scaled conditions were obtained by reducing the altitudes shown in Table 1 to the tunnel altitude and scaling the icing parameters while maintaining the parameters shown in Table 2 constant. For the Re-based scaling method, the Reynolds number, water loading, modified inertia parameter, and recovery temperature were kept constant. For the We_DA-based scaling method, air density based Weber number, water loading, modified inertia parameter, and recovery temperature were kept constant. For the WePi3-based scaling method, the air density-based Weber number, Pi3 mass ratio, modified inertia parameter, and recovery temperature were kept constant.

Table 1 and 2
There is apparently a typo in Table 2. I believe that what was intended is:

Scaling Method Scaling Parameters Held Constant
Re Re_2r    m_w    K_o    T_r
WePi3 We_DA    Pi3    K_o    T_r
We_DW We_DW    m_w    K_o    T_r

The test procedure was detailed:
[Emphasis added]

D. Test Procedure
For runback water to freeze in a manner similar to that at altitude, one of the conditions that needs to be met is that model surface temperatures need to be similar to those occurring at altitude. With the IPS operating at the same heated air mass flowrate and temperature, Reynolds number scaled conditions result in model surface temperatures nearly identical to those during operation at altitude conditions. This is generally true for both dry air and icing conditions, but more so for dry air. Because of this, the surface temperatures obtained at Re-scaled conditions could also be used as reference values.

When operating at Weber number scaled conditions, however, convective cooling by the tunnel airstream is elevated, resulting in a different model surface temperature profile. To compensate for the enhanced convective cooling, IPS system output is increased in temperature, mass flow rate, or both, to obtain the correct model surface temperature. Therefore, Weber number scaling methods require two steps: first run at Reynolds number scaled conditions to obtain the reference model surface temperatures, then run at Weber number scaled conditions adjusting the IPS system to get the model surface temperatures obtained in step one. These two steps are performed with dry air in the tunnel. The icing run may then commence at the Weber number scaled conditions to obtain runback icing results similar to those that would be expected at altitude.

Once the IPS parameters for the test were obtained, tests were done using the various scaling methods described in the introduction. The following describes the typical test procedure:
1) Set IPS air mass flow rate and temperature to obtain “reference” (Re-scaled) model leading edge temperature.
 2) Activate icing spray for a predetermined icing exposure time.
 3) Shut tunnel down and document the ice accretion using photographs. Perform 2D ice tracings, ice thickness measurements, and ice mass measurements. Record frozen rivulets using BIO-FOAM impression block.

Figure 1 and 2. Business jet coordinates. IRT model ice protection system cross section.
(From Papadakis, et al.)
Table 3. Descent scaled test conditions and ice mass.

Earlier test at the NRCC Altitude Icing Wind Tunnel (AIWT) (AIAA-2017-3926 3) showed that the WePi3 scaling matched a reference ice shape well, while Re scaling did not. A different airfoil and slightly different test conditions were used in that test.

Figure 6 from AIAA-2017-3926. Ice tracing from descent case reference and Re and We-Pi3 scaled conditions.
from AIAA-2017-3926

For this case, the scaling methods yielded slightly different results: Figure 6 and 7. Descent scenario ice tracing. Descent scenario upper surface ice accretion.

The heated surface temperatures were well-matched over most of the heated surface.
Figure 8. Descent scenario leadinge edge surface temperature.

Different heating levels were required to match the surface temperatures.
Figure 9. Descent scenario heated air temperature and energy inpur before and during icing exposure.

For another case, the scaling methods yielded different results: Figure 10 and 11. Cold Holed scenario upper surface ice accretion.

The advantages of the WePi3 method are discussed:

F. Further Discussion
Three things can happen to water striking a heated aircraft surface in flight icing conditions: it can runback and freeze on an unheated or insufficiently heated surface, it can be re-entrained into the airstream, or it can be evaporated. The air pressure at flight altitudes affects all three of these modes of mass transport. Reynolds number scaling provides the surface temperature conditions for freezing of runback water, but does not provide similitude in either liquid water re-entrainment into the airstream or evaporation. The result is a great deal more ice being frozen on the surface than would occur at altitude conditions. Weber number based on water density scaling, in conjunction with surface temperature matching, provides the inertia to surface tension forces ratio needed to remove much of the excess water that is frozen in the Reynolds number scaling method. Because convective cooling is, however, much enhanced through the elevated Reynolds number generated by this method, excess ice can still result. The Weber number based on air density and Pi3 method seeks to simulate all three modes of mass transport. Model surface temperature matching creates the surface condition for the ice to freeze in the proper location. Weber number based on air density matching generates ample inertia to surface tension forces to remove liquid water as would be the case at altitude, without over-enhancement of convective cooling through increased Reynolds number. Finally, the enhanced evaporation that occurs at altitude due to the decreased static pressure is addressed by reducing water loading in proportion to the reduction in calculated water evaporation rate.

I did not find further discuss of "surface tension forces to remove liquid water" from the surface. It is not clear to me if this was determined from observations of water leaving the surface, or if this is an assumption. Hopefully, this effect can be measured in the future.

Conclusions

[Emphasis added]

IV. Conclusions
A test was conducted at NASA Icing Research tunnel to evaluate altitude scaling methods for thermal ice protection system. These methods were developed during a series of joint NASA/NRC-Canada tests at NRCC Altitude Icing Wind Tunnel using a small symmetric airfoil model. The IRT allowed these scaling methods to be evaluated on a larger asymmetric business jet airfoil with a more typical IPS design at higher Reynolds number.
The results from the IRT test largely agreed with and supported the results from the AIWT tests. The We-based scaling methods resulted in smaller runback ice mass than the Re-based scaling method. The Re-based scaling method generated runback ice that formed farther downstream than the We-based methods. These results agreed with those from the AIWT tests where the scale-method ice accretions were compared with reference (altitude) results. The Weber number based on air density coupled with surface temperature matching and water loading scaling produced the most consistent results. While not perfect, this method appears to be the best available to scale thermal IPS icing test conditions for altitude effects in an atmospheric icing wind tunnel. Moreover, they are not based on empirically- generated scale factors, but on fundamental physics. What is left is to better determine the limits of the physical relations used which can be accomplished by testing full-scale airfoil models in an altitude capable wind tunnel.

While the procedures used were sound for research purposes, they may be less practical for airplane design. It is impractical to have flight test reference case results before one designs and tests an ice protection system in an icing wind tunnel. One must also have an assessment of the Pi3 term for the reference case, which requires an accurate heated surface leading edge temperature value in the icing condition.

Here, the researchers used the Re scaled condition as a substitute for the reference condition to obtain surface temperatures. While that may be feasible for airplane system design development, it increases the number of test steps for a given flight condition simulation. However, the reference heating is lower than the Re scaled by a small but unknown amount.

Figure 8 from AIAA-2017-3926. IPS operational data from descent case reference, Re and We-Pi3 scaled conditions.
from AIAA-2017-3926

With the WePi3 method, almost everything is scaled in test, except Weber number and surface temperature. While not explicitly addressed (the test conditions all used the same test time as the reference condition), time is scaled, as water catch rate m_w is scaled. This may not be an issue for steady state operation, but it does lead to challenges for simulating transient operation (entering a cloud, activating the system, deicing, etc.).

The scaling of the heating may be a conceptual roadblock to some, as one may wonder what exactly is being tested relative to flight conditions. The heating required for the WePi3 method is generally higher than that of the flight condition, which some may view as "non-conservative", if they do not understand the physics and testing of the scaling.

For a few, "worst case" conditions to simulate the maximum power capacity of the system, it may not be possible to scale the power up. For that case, using the WePi3 test conditions but with nominal power would be conservative.

Comparisons to NASA/CR-2004-212875 calculations

I used the methods from NASA/CR-2004-212875 2 to calculated similarity parameters.

There appears to be a difference in the way the We_da values are calculated. Using the NASA/CR-2004-212875 methods, the calculated We_da values matched approximately, except for the WePi3 case (about 5% difference). This suggests that the WePi3 case was run at a slightly too high (about 3%) of airspeed to match the Weber number. This may have had a rather small effect in the test, but is a challenge for those trying to reproduce the calculations.

Scale Method We_Da (Table 3) We_da (NASA/CR-2004-212875)
Reference 5814 5730
Re 4315 4351
WePi3 5814 6154
We_DW 7769 7808

Citations

An online search 4 found four citations of AIAA-2017-3927. I view this as under-valued for the excellent technical content.

Notes:


  1. Lee, Sam, Addy, Harold E. Jr., Broeren, Andy P., and Orchard, David M.: "Evaluation of Alternative Altitude Scaling Methods for Thermal Ice Protection System in NASA Icing Research Tunnel." AIAA-2017-3927, 9th AIAA Atmospheric and Space Environments Conference. 2017. ntrs 

  2. Anderson, David N.: Manual of scaling methods. No. E-14272, NASA/CR-2004-212875. 2004. ntrs 

  3. Orchard, D.M., Addy, H.E., Wright, W.B., and Tsao, J.: “Altitude Scaling of Thermal Ice Protection System in Running Wet Operation,”, AIAA-2017-3926. 9th AIAA Atmospheric and Space Environments Conference, May 5-9, 2017, Denver, CO 

  4. scholar.google.com 

social